AFPM Core Performance Testing: Plan Your Tests

Plan AFPM core performance testing: estimate iron mass and frequency, add measured loss data, and export a laboratory brief.

AFPM Core Test Planning Tool

Estimated iron mass: 4.16 kg · Electrical fundamental: 1000 Hz · Loss unknown: add matching measured W/kg.
1. Core geometry

Range: 60–600.

Range: 30–580.

Range: 8–150.

Updates instantly on this device. Required fields have defaults. Density and iron volume fraction are editable planning assumptions; presets are illustrative. Optional measurements remain unknown when blank.

Range: 3–96; whole numbers.

Range: 0.05–1.

Range: 5–9.

2. Excitation and fixture

Range: 100–35000.

Range: 2–32; whole numbers.

Range: 0.2–2.2.

Range: 4–50.

Range: 1–500; whole numbers.

Range: 1–200; whole numbers.

B peak is a target; saturation, current and source VA require a measured H(B) curve, gaps and winding data. Fixture selection describes the test request and does not establish standard conformity.

3. Optional measured data

Above 0 to 100,000 mm². Use the actual coil-linked core section normal to flux; do not use the annular face area or infer it from slot count.

Above 0 to 10,000 W/kg. Must match B, frequency, waveform, temperature and preload. Changing geometry, material, density or magnetic operating point clears this datum. Geometry/fixture changes also clear the flux section. No automatic PWM multiplier is applied.

Test measurement chain · conceptual arrangement
Excitation sourceN1 = 40Core + fixtureDefined flux sectionSense coil N220 turnsSynchronized V / IPhase calibrationVoltageCurrent

1000 Hz fundamental; effective section unknown. Fixture flux paths and return-yoke losses require validation.

Results and limits

Iron mass (all stators)
4.159 kg
Fundamental
1000.0 Hz
Secondary sine-reference EMF
Unknown: add flux section
Primary sine-reference EMF
Unknown: add flux section
Bandwidth screening target
200 kHz
Conditional total loss
Unknown: add matching W/kg

Voltage uses E = 4.44288 f N Bpk Ac for sinusoidal flux. Under PWM it is a fundamental reference; total RMS and peak voltage remain unknown. Both windings need a separate electrical safety assessment; these results do not establish SELV compliance.

Bandwidth is an editorial starting point: max(200 kHz, 10 × carrier, 10 × fundamental) for PWM; max(100 kHz, 10 × fundamental) for sine. It is not an IEC requirement. Verify spectral convergence, phase response and measurement uncertainty before instrument selection.

Loss = measured W/kg × estimated iron mass assumes uniform excitation and excludes unmeasured assembly effects. This is not the single-tooth fixture specimen power. Excitation current, amplifier VA, temperature rise and pass/fail status remain unknown.

Review method and evidence requirements

Review and share the test brief

Share the assumptions and unresolved measurements with your laboratory before choosing equipment.

Published by AxialFluxCore•••Methods, assumptions and open questions

Executive Testing Takeaways & Engineering Decisions

Four planning decisions drawn from method scopes and stated physical assumptions. Use the linked chapters to check evidence, limitations and the next measurement.

Ring ≠ tooth ≠ motor

Select a method for the specimen, not the motor label

IEC 60404-6 addresses eligible ring specimens. A return-yoke tooth rig needs a validated procedure; complete motor efficiency is a separate measurement. See Chapters 2 and 15.

No inferred PWM multiplier

Treat missing measurements as unknown

The tool needs matching measured W/kg before it reports conditional total loss. Carrier frequency alone cannot determine material loss. See Chapters 3 and 4.

Measured section required

Keep geometry estimates separate from instrument ratings

Faraday voltage uses a supplied effective flux section. Neither stator envelope mass nor a voltage estimate establishes amplifier VA or electrical safety. See Chapters 1 and 5.

Limits agreed by buyer + lab

Agree the evidence and acceptance plan before testing

Record waveform, temperature, preload, specimen identity and uncertainty. Coupons, assembled stators and motors answer different release questions. See Chapters 6, 12 and 16.

Planning audiences (method scope still requires review)

  • • OEM traction motor teams comparing segmented or annular stator cores.
  • • Propulsion R&D teams planning a frequency and waveform test matrix.
  • • Industrial robotics and precision servo actuators requiring high torque-to-inertia ratios.
  • • Industrial drive buyers defining component evidence before motor validation.

Boundary Exclusions (Out of Scope for This Guide)

  • • Generic grid-connected 50/60 Hz radial flux induction motor lamination testing.
  • • Low-speed multi-megawatt direct-drive wind turbine generators without back-iron.
  • • Consumer DIY hobbyist brushless DC (BLDC) drone outrunners without core laminations.
  • • Third-party distributor marketplace pricing or commercial inventory listings.
Methods and Decision Evidence

In-Depth Engineering Chapters: AFPM Core Performance Testing

Sixteen chapters distinguish measured data, physical calculations and editorial planning guidance. Numeric acceptance limits and laboratory capabilities require agreement.

1Chapter 1 of 16

B-H loops: what the test actually measures

Separate measured flux and field from envelope-based planning estimates.

For a linked search coil, e2 = −N2 dΦ/dt. With a defined effective section, integration gives average B. Establish polarity, offset correction and the coil-linked area before comparing loops. Air-flux pickup and integration drift belong in the uncertainty budget.

For sinusoidal flux only, E_rms = 4.44288 f N Bpk Ac. The calculator uses this relation when the section is supplied. A PWM selection changes the interpretation to a fundamental reference; it does not predict pulse peaks or total RMS.

The tool estimates iron mass from annular envelope volume × iron volume fraction × density × stator count. The fill input represents occupied iron volume, not winding fill. Use weighed specimen mass and drawing-derived sections for acceptance work.

Physical Relation / Stated Approximation:E_rms = 4.44288 × f × N × Bpk × Ac (Ac in m²; sine flux)
B-H loops: what the test actually measures: evidence workflow
1. Define section2. Integrate sense V3. Check B waveform

Method sequence; no measured performance curve or invented data.

B-H loops: what the test actually measures — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
MassEnvelope + volume fractionReplace with weighed specimen
Flux sectionUser-supplied effective areaUnknown if blank
H(B), current, VANot calculatedMeasure fixture and winding response

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: IEC 60404-6:2018

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Ask the lab for raw synchronized traces and its section/mass definitions.
2Chapter 2 of 16

Choose a specimen: sheet, ring, tooth or assembly

Each fixture answers a different question and has different correction costs.

IEC 60404-6 covers selected metallic and powder ring materials and explicitly excludes electrical steels and soft ferrites. Calling every AFPM core test an IEC 60404-6 test would overstate applicability.

IEC 60404-2 concerns electrical steel sheet/strip in an Epstein frame; its public base scope specifies AC measurements up to 400 Hz. Cutting representative sheet samples does not reproduce tooth-edge damage, assembly stress or a multi-axis operational flux path.

A custom tooth fixture can preserve production geometry and reduce the material needed for an experiment. It also adds return-yoke loss, contact gaps, fixture heating and flux nonuniformity. Establish repeatability and a correlation to assembly measurements; no universal cost saving or correlation percentage is available.

Choose a specimen: sheet, ring, tooth or assembly: evidence workflow
1. Identify specimen2. Match method scope3. Validate fixture

Method sequence; no measured performance curve or invented data.

Choose a specimen: sheet, ring, tooth or assembly — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
Electrical steel stripEpstein/sheet methodCheck frequency scope
Eligible SMC ringIEC 60404-6 ring methodNot a whole motor result
Finished toothCustom return-yoke rigSeparate fixture-loss correction

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: IEC 60404-6:2018IEC 60404-2:1996 + AMD1:2008

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Choose the smallest specimen that preserves the failure mechanism you need to investigate.
3Chapter 3 of 16

Loss models require fitted data

Use loss separation as a calibrated model, not a material lookup promise.

A hysteresis/classical/excess decomposition is one possible engineering model. Fit it to a documented set of measured frequency and B points, with consistent units, waveform, specimen processing and temperature.

No validated coefficients are provided here for Somaloy, NOES, amorphous or nanocrystalline products. Grade names alone do not determine a loss surface. The calculator accepts measured specific loss and applies P = p_specific × mass without a hidden correction.

Hold back independent points for checking residuals and disclose the fitted range. Do not extrapolate through saturation, change from alternating to rotational flux, or transfer coefficients between heat treatments without new evidence.

Physical Relation / Stated Approximation:P_core = p_specific (W/kg) × m_iron (kg)
Loss models require fitted data: evidence workflow
1. Measure loss map2. Fit coefficients3. Check held-out points

Method sequence; no measured performance curve or invented data.

Loss models require fitted data — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
Hysteresis termFit from measured loopsNo grade coefficient supplied
Classical/excess termsModel-dependent separationReport parameter correlation
Outside fit rangeUnknownMeasure additional points

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: IEC 60404-6:2018

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Request the measured map and residuals alongside any fitted coefficients.
4Chapter 4 of 16

PWM: measure the waveform you intend to use

Avoid attributing a generic material loss penalty to a motor standard.

IEC 60034-2-3:2024 is an International Standard for converter-fed motor loss and efficiency methods. It is not “IEC TS 60034-2-3:2024”, and its public scope does not establish fixed material loss multipliers.

For a useful comparison, hold fundamental B, frequency, temperature, specimen and preload consistent while changing the recorded drive waveform. Capture carrier, modulation, DC bus and relevant switching behavior. The difference is specific to that experiment.

A sine datum must not be relabelled as PWM loss. Supply a matching PWM measurement to the tool or leave loss unknown. Changing waveform, carrier, frequency or B clears the supplied datum to prevent reuse at a different operating point.

Physical Relation / Stated Approximation:Measured waveform ratio = P_PWM / P_sine (matched test conditions)
PWM: measure the waveform you intend to use: evidence workflow
1. Match operating point2. Record drive waveform3. Compare measured loss

Method sequence; no measured performance curve or invented data.

PWM: measure the waveform you intend to use — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
Sinusoidal loss onlyPWM result unknownRequest matched waveform test
Matching PWM W/kgConditional mass scalingNo extra multiplier
Motor efficiencyComplete motor testDo not infer from core loss

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: IEC 60034-2-3:2024

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Specify actual drive conditions in the RFQ rather than a generic PWM percentage.
5Chapter 5 of 16

Bandwidth and phase response: build an uncertainty budget

A high bandwidth number alone does not validate a low-power-factor measurement.

Active power depends on voltage-current phase alignment as well as amplitude accuracy. For a single sinusoidal component, the magnitude of the small-angle relative error is approximately |tan φ × Δθ|. This first-order example is not a complete broadband uncertainty calculation.

Illustrative arithmetic: at power factor 0.035, a 10 ns skew at 25 kHz gives Δθ = 0.001571 rad and about 4.49% relative power error. These are chosen example inputs, not measured laboratory performance or mandatory instrument tolerances.

The calculator’s bandwidth target is an editorial screening heuristic, not an IEC requirement. Check convergence as measurement bandwidth changes, probe loading, anti-alias filtering, phase response and calibration across the measured spectrum. Separate sample rate from analog bandwidth.

Physical Relation / Stated Approximation:|ΔP/P| ≈ |tan φ| × 2πf × |Δt| (small phase error; one sine component)
Bandwidth and phase response: build an uncertainty budget: evidence workflow
1. Calibrate V / I2. Check phase + spectrum3. State uncertainty

Method sequence; no measured performance curve or invented data.

Bandwidth and phase response: build an uncertainty budget — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
Analog bandwidthFrequency responseCheck amplitude and phase
SamplingAnti-aliasing and synchronizationNot interchangeable with bandwidth
Low power factorPhase uncertainty dominatesConsider an independent loss cross-check

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: IEC 60404-6:2018

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Ask the lab for uncertainty at your waveform and power factor before selecting equipment.
6Chapter 6 of 16

Clamping and assembly stress

Test the mechanical state that the motor will impose.

Clamping, potting cure and housing fits can change the magnetic response. The direction and size depend on material, processing and stress orientation; this page has no validated universal degradation coefficient.

Compare baseline and loaded specimens at matching B, frequency, waveform and temperature. Record force, contact area, pressure distribution, fixture compliance and whether unloaded properties recover.

A destructive strength test and a magnetic test under preload answer different questions. ISO 3325:2026 concerns eligible sintered specimens; do not assume its applicability to a non-sintered SMC tooth or use it as a preload acceptance limit.

Clamping and assembly stress: evidence workflow
1. Measure baseline2. Apply known preload3. Retest + unload

Method sequence; no measured performance curve or invented data.

Clamping and assembly stress — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
BaselineUnloaded specimenRecord handling state
Operating preloadRepresentative support/contactMap pressure uncertainty
Post-unloadCheck irreversible changeInvestigate cracks or coating damage

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: ISO 3325:2026

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Agree preload and support geometry with the assembly engineer, then test the matched states.
7Chapter 7 of 16

Temperature: distinguish material loss from cooling behavior

A temperature-rise test is not a direct substitute for a loss measurement.

Compare magnetic measurements at specified stabilized specimen temperatures and record drift during each run. The temperature trend is grade- and process-dependent; no universal loss coefficient or SMC binder failure temperature is supplied.

The tool scales a supplied W/kg datum but does not predict temperature rise. Thermal resistance, heat capacity, cooling boundary conditions and nonuniform heat generation are not inputs.

For a calorimetric cross-check, define the system boundary, sensor calibration and parasitic heat paths. A transient balance P ≈ Cth dT/dt needs corrections for heat flow and stored energy in fixtures; it is not automatically a traceable replacement for electrical measurement.

Physical Relation / Stated Approximation:Thermal balance: P_in − P_out = Cth × dT/dt (lumped approximation)
Temperature: distinguish material loss from cooling behavior: evidence workflow
1. Stabilize temperature2. Measure at fixed B / f3. Check reversibility

Method sequence; no measured performance curve or invented data.

Temperature: distinguish material loss from cooling behavior — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
Material testKnown specimen temperatureLoss map with uncertainty
Assembly thermal testKnown coolant and mountingHotspot/temperature rise
Transient calorimetryCalibrated system heat capacityCorrect parasitic heat paths

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: IEC 60404-6:2018

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Request both a temperature-conditioned magnetic map and a separate assembly thermal plan.
8Chapter 8 of 16

Insulation: sheet surfaces, particles and windings differ

Avoid assigning an unrelated mechanical standard to electrical insulation.

ASTM A717/A717M addresses surface insulation resistivity of electrical steel strips/punchings under specified conditions. It does not measure bulk SMC particle insulation or qualify a motor winding dielectric system.

For SMC, agree an appropriate bulk resistivity method and specimen geometry with the material supplier and lab. Correlate any screening metric with loss and processing data; no universal acceptance value is established here.

ISO 3325:2026 is a transverse rupture strength method. It does not measure particle insulation. Mechanical strength, electrical resistivity and winding insulation each require separate evidence.

Insulation: sheet surfaces, particles and windings differ: evidence workflow
1. Identify insulation2. Select matching method3. Agree acceptance limit

Method sequence; no measured performance curve or invented data.

Insulation: sheet surfaces, particles and windings differ — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
Sheet surface coatingASTM A717 scopeNot winding dielectric strength
SMC bulk resistivityAgreed validated methodNo universal threshold supplied
Winding insulationSeparate system qualificationOutside this core-loss calculator

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: ASTM A717/A717MISO 3325:2026

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Put the insulation object and method explicitly in the test request.
9Chapter 9 of 16

Local and rotational flux: recognize a scalar model’s limits

A coil-linked average cannot establish a 3D tooth hotspot.

An AFPM core can experience spatially varying flux directions near interfaces and tooth regions. A scalar ring or tooth measurement cannot reconstruct a complete rotational loss map.

A field probe samples the field at its sensing position, which may include air/fringing fields. Calibrate sensor orientation and position; do not equate an external Hall reading with internal bulk B without a validated relation.

Use a documented electromagnetic model to identify representative regions, then obtain suitable material or component measurements. No universal rotational-to-alternating loss ratio is supplied or used by the calculator.

Local and rotational flux: recognize a scalar model’s limits: evidence workflow
1. Locate critical region2. Measure/model vector B3. Validate local loss

Method sequence; no measured performance curve or invented data.

Local and rotational flux: recognize a scalar model’s limits — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
Search coilLinked flux averageNot a local vector map
Hall/field probeField at sensing positionPosition and orientation matter
Rotational loss rigControlled vector excitationRequires a separate loss surface

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: IEC 60404-6:2018

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Treat tooth-tip and interface loss as unresolved until validated against representative measurements.
10Chapter 10 of 16

Modal checks under representative assembly conditions

Mode frequencies depend on supports, preload and assembled mass.

An impact or shaker test can identify resonant behavior, but a free tooth and a potted stator have different boundaries. Record mounting, accelerometer mass, excitation location and temperature.

Compare measured mode shapes and damping with electromagnetic excitation orders over the operating speed range. A single natural frequency cannot guarantee acceptable motor noise or fatigue life.

Start with component screening if it answers a specific defect question; validate final risk on the representative assembly. There is no claimed universal modal threshold or test duration here.

Modal checks under representative assembly conditions: evidence workflow
1. Define support state2. Measure modal response3. Compare operating orders

Method sequence; no measured performance curve or invented data.

Modal checks under representative assembly conditions — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
Loose componentMaterial/process comparisonLimited assembly correlation
Clamped/potted statorRepresentative boundariesInclude preload and temperature
Complete motorOperational responseRequires operating validation

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Editorial test-planning guidance. No standard-specific limits or verified laboratory performance are asserted in this chapter; validate the procedure with your laboratory.

Next action: Request mode shapes and boundary conditions, not just a peak-frequency number.
11Chapter 11 of 16

Density and strength: preserve process traceability

A nominal density in the calculator is an editable assumption.

The material dropdown supplies approximate planning densities. These are not certified grade values; replace them with measured density or mass and account for coatings, voids and nonmagnetic inserts.

ISO 3369:2006 is limited to impermeable sintered materials and hardmetals. Porous or non-sintered SMC parts need an appropriate method agreed with the lab; liquid ingress and specimen preparation can change a density result.

ISO 3325:2026 concerns transverse rupture strength of eligible sintered materials. Confirm specimen and process applicability before quoting it for a pressed SMC product. A coupon result alone does not establish tooth retention strength.

Physical Relation / Stated Approximation:Estimated mass = annular envelope volume × iron volume fraction × density × stator count
Density and strength: preserve process traceability: evidence workflow
1. Identify batch2. Measure mass / density3. Correlate process data

Method sequence; no measured performance curve or invented data.

Density and strength: preserve process traceability — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
Density inputApproximate editable assumptionUse measured batch data
ISO 3369Impermeable sintered scopeCheck porosity and process
ISO 3325Sintered specimen strengthNot assembled retention strength

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: ISO 3369:2006ISO 3325:2026

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Retain compaction/heat-treatment revision and specimen identity with every reported value.
12Chapter 12 of 16

Repeatability, reproducibility and acceptance decisions

Agree guard bands before comparing a result with a limit.

Repeated reads without removing a specimen assess a different source of variation from rewinding, reclamping or changing operator. Design repeats around the actual decision risk.

List uncertainty contributions from mass, section, waveform control, voltage/current sensing, phase, temperature and fixture subtraction. Report the coverage convention and do not claim a universal accuracy from a standard name alone.

Agree what happens when uncertainty overlaps the buyer’s limit: retest, investigate or apply a documented decision rule. This page has no universal pass/fail threshold or production release authority.

Repeatability, reproducibility and acceptance decisions: evidence workflow
1. Repeat setup2. Budget uncertainty3. Apply agreed rule

Method sequence; no measured performance curve or invented data.

Repeatability, reproducibility and acceptance decisions — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
Same setup repeatsShort-term stabilityDo not imply reproducibility
Re-fixture/operator repeatsSetup sensitivityRecord repeat protocol
Near a limitDecision uncertaintyAgree guard band / retest

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: IEC 60404-6:2018

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Request raw results, uncertainty and the decision rule in the same release record.
13Chapter 13 of 16

EOL screening: establish correlation first

Coercivity can support process checks without replacing the full loss map.

IEC 60404-7:2019 covers open-circuit coercivity measurement. Its scope does not establish an eight-second cycle, a particular heat treatment or a universal relationship between Hc and high-frequency loss.

Build a correlation using representative good and intentionally varied process specimens, then verify false accept/reject behavior against the detailed magnetic test. Demagnetization history, geometry and ambient fields belong in the procedure.

Production sampling and test takt require a validated line study. Keep the detailed characterization route for changes in material, process or fixture correlation. No automated release threshold is specified here.

EOL screening: establish correlation first: evidence workflow
1. Characterize reference lots2. Correlate screening metric3. Monitor drift

Method sequence; no measured performance curve or invented data.

EOL screening: establish correlation first — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
Coercivity screenProcess proxyNot a complete AC loss map
Detailed AC testOperating-point evidenceSlower / more fixture work
Line taktUnknown until demonstratedValidate handling and repeatability

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: IEC 60404-7:2019

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Use a process screen only after its correlation and escape risk are documented.
14Chapter 14 of 16

Design a test matrix that controls cost and rework

Separate exploratory tests from qualification evidence.

Begin with the buyer’s decision: material ranking, process troubleshooting, assembly validation or production screening. Allocate B/f/temperature/preload points to that question rather than ordering every test at once.

Fixture design, winding changes, thermal soak, calibration and destructive samples can dominate cost and lead time. Quote them separately; no public price or guaranteed percentage saving is available on this page.

A staged approach can begin with matched coupons, then finished teeth, then representative assemblies. Set a review gate at each transfer so a correlation failure is found before committing to full motor tests.

Design a test matrix that controls cost and rework: evidence workflow
1. Define decision2. Stage specimen tests3. Release next budget

Method sequence; no measured performance curve or invented data.

Design a test matrix that controls cost and rework — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
ExploratorySmall targeted matrixFind dominant uncertainty
QualificationAgreed limits and repeatsBudget fixture / soak time
Change controlTargeted requalificationCheck correlation after changes

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Editorial test-planning guidance. No standard-specific limits or verified laboratory performance are asserted in this chapter; validate the procedure with your laboratory.

Next action: Ask for a staged quotation with sample consumption, setup effort and explicit stop/review points.
15Chapter 15 of 16

Core loss versus complete motor efficiency

Do not turn a component measurement into a system efficiency claim.

IEC 60034-2-3:2024 addresses converter-fed AC motor loss and efficiency methods. Core material loss is only one contribution; it cannot establish efficiency without the other losses and an appropriate motor test.

The tool includes no copper, magnet, mechanical, windage, inverter or cooling losses. It also assumes uniform mass scaling for the supplied specific loss, which may fail across a nonuniform assembled stator.

Use component measurements to inform a documented model and then validate the complete motor under an agreed operating-point procedure. Keep motor results distinct from material and fixture results in the report.

Core loss versus complete motor efficiency: evidence workflow
1. Measure component loss2. Assemble loss budget3. Validate complete motor

Method sequence; no measured performance curve or invented data.

Core loss versus complete motor efficiency — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
Material W/kgSpecified specimen stateNot motor efficiency
Estimated stator wattsConditional mass scalingNot a thermal guarantee
Motor efficiencyComplete test and loss budgetUse applicable motor procedure

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: IEC 60034-2-3:2024

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Request separate component and motor evidence rather than a single implied efficiency number.
16Chapter 16 of 16

RFQ and release evidence checklist

Turn the calculator output into an actionable laboratory request.

Attach the drawing revision, grade/process state, specimen count, dimensions, mass basis and requested operating matrix. Include NDA/file-handoff preferences and identify which values are measured, assumed or still unknown.

Request waveform traces, raw results, calibration records, uncertainty, fixture-loss treatment and the agreed acceptance rule. Where independent accreditation is needed, verify the named laboratory’s current scope against the actual method.

AxialFluxCore can review the request and confirm available options. This page does not establish an owned accredited lab, guaranteed test capability, turnaround time, PPAP package or successful customer outcome. Agree those deliverables before ordering.

RFQ and release evidence checklist: evidence workflow
1. Share brief + drawing2. Agree scope + limits3. Review evidence package

Method sequence; no measured performance curve or invented data.

RFQ and release evidence checklist — decision checklist

Editorial planning guidance; thresholds and test conditions require buyer/laboratory agreement.

Item / methodWhat it establishesBoundary / next evidence
Buyer suppliesDrawing / conditions / decisionRecord revision and unknowns
Lab confirmsMethod / capability / uncertaintyVerify accredited scope if needed
Release recordResults / rule / approvalsNo automatic page pass/fail

Note: No universal grade property, acceptance limit or laboratory capability is implied.

Scope sources: IEC 60404-6:2018IEC 60034-2-3:2024

Sources support the stated method scope. Planning checklists and examples are editorial; no universal acceptance limits are asserted.

Next action: Copy the brief, mark unresolved inputs and request an engineering review.

Reproduce the sinusoidal voltage example

This tool run was captured on 2026-11-07. Start with Reset Defaults, select sinusoidal excitation, set speed to 3,000 rpm (10 pole pairs, 500 Hz), Bpk to 1.0 T, effective section to 100 mm², primary turns to 20 and secondary turns to 10. Leave measured W/kg blank. E2 = 4.44288 × 500 × 10 × 1 × 100e−6 = 2.22 Vrms; E1 = 4.44 Vrms. Loss remains unknown.

AFPM core performance testing calculator run showing 500 Hz, 2.22 Vrms secondary and 4.44 Vrms primary reference voltage with unknown loss
Actual software execution, cropped to the results panel; site navigation and inputs are outside the crop. This records calculator behavior, not a physical core measurement, customer result or laboratory certification.
Illustrative Planning Scenarios

Hypothetical Worked Validation Scenarios

Three hypothetical examples show a reproducible voltage calculation, a PWM evidence gap and dual-stator mass accounting. They are not measured customer outcomes.

Laboratory planning

Hypothetical sine-reference voltage check

Premise: Chosen example inputs: effective section 100 mm², 500 Hz, Bpk 1.0 T, N2 10, N1 20.

Challenge: Separate a reproducible voltage calculation from equipment and safety approval.

Test Protocol: Enter the chosen values in sinusoidal mode. E2 = 4.44288 × 500 × 10 × 1 × 100e−6; E1 uses 20 turns.

Findings: Arithmetic gives E2 = 2.22 Vrms and E1 = 4.44 Vrms. Excitation current, VA, core loss and electrical safety remain unknown.

Remaining Verification: Measure the actual effective section, H(B), waveform, winding and fixture response before selecting hardware.
Traction R&D

Hypothetical PWM data gap

Premise: The buyer has a sinusoidal loss map, while the planned motor uses PWM.

Challenge: A carrier setting alone cannot convert that map into validated PWM loss.

Test Protocol: Select PWM and leave W/kg blank; request matching waveform tests at the target B, frequency, temperature and preload.

Findings: The tool reports mass and frequency while loss remains unknown. No assumed harmonic multiplier or delivered efficiency improvement is claimed.

Remaining Verification: Agree waveform capture, fixture-loss correction and uncertainty; then enter the matching measured datum.
OEM comparison

Hypothetical dual-stator mass check

Premise: Two stators have identical OD, ID, thickness, density and iron fraction.

Challenge: Avoid comparing one-stator and two-stator mass bases.

Test Protocol: Change only topology from single-stator to DSSR and restore the same iron volume fraction after the topology default changes.

Findings: The geometric model doubles estimated total iron mass. Conditional loss doubles only if the same measured W/kg genuinely applies to both stators.

Remaining Verification: Weigh each stator and verify excitation uniformity and assembly effects; this is an accounting example, not a measured motor result.
Frequently Asked Questions

Technical FAQ: AFPM Core Performance Testing

Twenty-four answers cover magnetic section definitions, PWM evidence, clamping, temperature-conditioned measurements, phase error and RFQ planning.

Electrical & Magnetic Characterization

Can I use the annular stator face area as the flux section?

Only if it is actually the effective coil-linked section normal to the measured flux. Ring, tooth and back-iron paths differ. Supply a drawing-derived or measured section; the tool leaves voltage unknown if it is blank.

Electrical & Magnetic Characterization

Why are excitation current and amplifier VA unknown?

A grade name and envelope dimensions do not specify nonlinear H(B), gaps, winding impedance, current waveform or fixture losses. Measure or model those inputs with the laboratory before selecting the source.

Electrical & Magnetic Characterization

What does the iron volume fraction mean?

It is occupied iron volume divided by the annular envelope volume, per stator. It is not copper fill. Verify it from the geometry or replace estimated mass with a weighed specimen for acceptance work.

Electrical & Magnetic Characterization

Does a ring test qualify a finished tooth?

It establishes properties of the tested specimen under the stated conditions. A finished tooth can introduce processing stress, gaps and return-yoke corrections. Demonstrate transfer with matched component tests.

High-Frequency Inverter Harmonics

Does IEC 60034-2-3:2024 specify a fixed PWM core loss penalty?

The cited publication concerns converter-fed motor loss and efficiency methods. This page has no evidence for a universal material multiplier, so the calculator does not add one.

High-Frequency Inverter Harmonics

Can I enter sine W/kg while PWM is selected?

Use only a datum measured at the selected waveform and operating point. If only sine data exists, select sine to examine that baseline or leave PWM loss unknown and request a matching test.

High-Frequency Inverter Harmonics

Does the voltage output predict PWM pulse peaks?

No. It is the sinusoidal-flux fundamental reference. PWM total RMS, switching peaks and insulation requirements need recorded waveform and winding data.

High-Frequency Inverter Harmonics

Why is specific loss cleared after I change B or frequency?

The previous datum may no longer apply. Changing material, frequency, B, waveform, carrier, topology or fixture clears it so you can enter matching data explicitly.

Mechanical & Clamping Integrity

Is there a universal clamping-pressure limit for SMC?

No limit is established here. Material processing, geometry, contact support and loading direction matter. Agree loads with the assembly engineer and test representative specimens.

Mechanical & Clamping Integrity

Does ISO 3325 measure SMC insulation?

No. ISO 3325:2026 concerns transverse rupture strength of eligible sintered materials. It is not an electrical insulation method; applicability to non-sintered SMC must be established.

Mechanical & Clamping Integrity

Can a loose-tooth resonance predict assembled motor noise?

It can support component comparison, but assembled modes depend on potting, supports, preload and temperature. Validate representative assembly response and operating excitation orders.

Mechanical & Clamping Integrity

How should I compare stressed and unstressed magnetic behavior?

Keep B, frequency, waveform and temperature matched, document contact geometry and preload, and retest after unloading to identify reversible versus permanent changes.

Thermal & Hotspot Mapping

Does calculated core loss give temperature rise?

No. Cooling conditions, thermal paths, heat capacity and local heat sources are missing. Use a separate thermal model and representative assembly test.

Thermal & Hotspot Mapping

Can I use a room-temperature datum at operating temperature?

Only if supporting characterization establishes that transfer. Otherwise request temperature-conditioned measurements and keep the unmeasured condition unknown.

Thermal & Hotspot Mapping

When is transient calorimetry useful?

As an independent loss cross-check when heat capacity, sensor response and parasitic heat flows are characterized. The simple Cth dT/dt approximation is not enough by itself.

Thermal & Hotspot Mapping

Are the scenarios measured customer results?

No. They are explicitly hypothetical planning examples or arithmetic checks. They do not demonstrate a delivered product, certification or customer performance.

Instrumentation & Bench Architecture

Is 10 times carrier bandwidth a standard requirement?

It is an editorial screening heuristic used by this tool. The final choice needs spectrum, phase-response, convergence and uncertainty checks for the actual measurement.

Instrumentation & Bench Architecture

Why can tiny probe delays matter?

At low power factor, relative active-power error is sensitive to voltage-current phase mismatch. The chapter gives a first-order single-frequency arithmetic example; broadband work needs a fuller uncertainty budget.

Instrumentation & Bench Architecture

Is a low voltage result evidence of SELV compliance?

No. Neither the estimated secondary nor primary voltage establishes electrical safety. Pulse peaks, insulation, stored energy, environmental conditions and equipment design require separate assessment.

Instrumentation & Bench Architecture

What if copying is blocked by my browser?

The tool focuses and selects the generated brief. Use Ctrl+C or Cmd+C, or touch and hold to copy. You can also open the prefilled engineering inquiry and review the text there.

Standards & Automotive Quality

Does the tool issue a pass/fail certificate?

No. Buyer and laboratory must agree the applicable method, conditions, limits, uncertainty and decision rule. The output is a planning brief.

Standards & Automotive Quality

Is IEC 60404-6 appropriate for electrical steel?

Its cited public scope excludes electrical steels and soft ferrites. Select an applicable sheet or component procedure with the lab, including the required frequency range.

Standards & Automotive Quality

Does coercivity screening replace AC loss testing?

No. IEC 60404-7 covers coercivity measurement. A production correlation to the desired loss property must be demonstrated and monitored before screening is used for release.

Standards & Automotive Quality

What should an OEM request before placing a test order?

Request method and edition, specimen preparation, operating matrix, sample consumption, fixture corrections, uncertainty, decision rule, named laboratory capability and a separate quote for setup and recurring tests.

Traceability & Standards

Primary Standards: Scope and Applicability

Source scopes checked against public publisher descriptions on 2026-11-07. Full standards may require purchase; verify the applicable edition and procedure with the laboratory. Editorial checklists and arithmetic examples are not standard-mandated limits or measured results.

IEC 60404-6:2018

AC ring-specimen magnetic measurements

Eligible metallic/powder ring specimens, 20 Hz–100 kHz; excludes electrical steels and soft ferrites. The public abstract supports scope, not universal accuracy or fixture conformity.

IEC2018; amendment 2021
IEC 60034-2-3:2024

Loss and efficiency testing of converter-fed AC motors

Complete converter-fed AC motor methods and interpolation; not a prescribed material PWM-loss multiplier or a stand-alone tooth test method.

IEC2024
IEC 60404-7:2019

Open-circuit coercivity measurement

Coercivity measurement; does not establish an eight-second takt time, heat-treatment recipe or universal rejection threshold.

IEC2019
IEC 60404-2:1996 + AMD1:2008

Electrical steel sheet and strip: Epstein frame

Sheet/strip magnetic characterization; published base scope includes AC up to 400 Hz. Agree a different applicable method for higher-frequency component tests.

IEC1996; amendment 2008
ASTM A717/A717M

Surface insulation resistivity of single-strip specimens

Electrical-steel strip/punching surface insulation test under specified conditions. Not a bulk SMC particle-insulation or winding dielectric test. Public method listing; verify contracted edition.

ASTMEdition to be agreed
ISO 3325:2026

Transverse rupture strength of sintered metal materials

Mechanical strength method for eligible sintered specimens; applicability to a pressed, non-sintered SMC grade must be established. Not an insulation method.

ISO2026
ISO 3369:2006

Density of impermeable sintered materials and hardmetals

Density method limited to its material and permeability scope. Do not apply it automatically to porous or resin-bonded SMC; agree a suitable density method.

ISO2006

Ready to Qualify Your Axial Flux Stator Core Performance?

Share your core geometry, operating conditions and required evidence. We can review the request and confirm available testing options, named laboratory capability, scope, cost and delivery before you place an order.

Direct engineering inquiries: [email protected]